SEALING EXPANSION JOINTS WITH FLOWING WATER

Specs 26

PRODUCTS REQUIRED

Choose one

Out of stock

Choose one

Choose one

JOINT DESIGN REQUIREMENTS

  • Maximum joint width: 30mm
  • Minimum depth: half the joint width

APPLICATION REMINDERS

  1. Prepare a clean, sound joint
  2. Prime joint faces with Part A
  3. Fill and compact the sealant

JOINT TREATMENT DETAIL

METHOD

  1. Remove all loose, unsound or contaminated material. Joint faces must be clean, stable and free from dust, laitance, oil and debris.
  2. Cut a channel at the expansion joint to a minimum of 60 mm wide and 60 mm deep.
  3. Fill up the joint with MAXPLUG to stop the flowing water.
  4. Leave to cure for 5-10 minutes.
  5. Cut out a new channel in the centre of the cured MAXPLUG to a width no less than 5mm wide for MAXJOINT ELASTIC or 10mm wide for MAXJOINT ELASTIC EXPRESS and does not exceed 30mm wide.
  6. The joint depth must be at least half the joint width, with a minimum of 5mm deep for MAXJOINT ELASTIC or 10mm deep MAXJOINT ELASTIC EXPRESS and does not exceed 30mm deep.
  7. Thoroughly dampen the joint surfaces with clean water. Remove standing or excess water before application.
  8. Prime both sides of the joint using Part A (liquid component) of MAXJOINT ELASTIC.
  9. Mix equal parts of liquid and powder in accordance with Technical Bulletin until smooth and uniform.
  10. Apply MAXJOINT ELASTIC firmly into the joint, ensuring complete filling and full contact with both sides.
  11. Tool to the required profile and remove excess material with a damp sponge before the product begins to set.

IMPORTANT

All products must be used in accordance with the current Technical Bulletins and specific project requirements, including requirements relating to dimensions, surface preparation, mixing, and application.