0

SEALING WALL / FLOOR JOINTS

Specs 26

PRODUCTS REQUIRED

Choose one (MAXPLUG / MAXJOINT ELASTIC or MAXJOINT ELASTIC EXPRESS)

Out of stock

Choose one

Out of stock

Out of stock

Choose one

JOINT DESIGN REQUIREMENTS

  • Minimum width/depth:
    • 5 mm for MAXJOINT ELASTIC
    • 10 mm for MAXJOINT ELASTIC EXPRESS
    • 20mm for MAXPLUG
  • Maximum width/depth: 30mm

APPLICATION REMINDERS

  1. For active water leaks use MAXPLUG
  2. Where movement or flexibility is Required use MAXJOINT ELASTIC or MAXJOINT ELASTIC EXPRESS
  3. Apply MAXSEAL FLEX or MAXSEAL FLEX M in two coats and reinforce the junction with MAXMESH
  4. Thoroughly wet the surface before each application of DRIZORO product

JOINT TREATMENT DETAIL

METHOD

  1. Prepare the area by removing all loose, friable or contaminated material to provide a clean, sound substrate.
  2. Cut a continuous channel at the wall-to-floor junction
    1. Where active water flow is present a minimum of 20 mm wide and 20 mm deep for MAXPLUG
    2. No active water a minimum of 5 mm wide and 5 mm deep for MAXJOINT ELASTIC or 10mm wide and 10 mm deep for MAXJOINT ELASTIC EXPRESS
  3. Where active water flow is present, tightly fill the prepared channel with MAXPLUG. Where there is no active water flow, fill the channel with MAXJOINT ELASTIC or MAXJOINT ELASTIC EXPRESS.
  4. Allow the selected repair product to cure in accordance with the relevant DRIZORO technical data sheet before proceeding.
  5. Thoroughly wet the wall, repaired joint and floor. The substrate must be saturated, with no standing water.
  6. Apply the first coat of MAXSEAL FLEX or MAXSEAL FLEX M over the repaired joint, extending 100 mm up the wall and 100 mm onto the concrete floor.
  7. While the first coat remains wet, embed the 200mm wide MAXMESH centrally over the wall-to-floor junction and lightly cover the mesh with MAXSEAL FLEX or MAXSEAL FLEX M.
  8. Allow the first coat to cure for a minimum of 14 hours for MAXSEAL FLEX or 6 hours MAXSEAL FLEX M. Thoroughly wet the surface and apply the second coat of MAXSEAL FLEX or MAXSEAL FLEX M over the reinforced area.

IMPORTANT

All products must be used in accordance with the current Technical Bulletins and specific project requirements, including requirements relating to dimensions, surface preparation, mixing, and application.