SEALING FRACTURES IN SUSPENDED CONCRETE SLABS

Products required

Method

  1. Prepare area to be treated by removing any loose materials ensuring a clean and sound surface.
  2. Using a grinding wheel, open the fracture to a width of 10mm and a depth of 20mm.
  3. Remove any debris from the newly formed void and moisten with primer (part A ) of MAXJOINT ELASTIC.
  4. Apply MAXJOINT ELASTIC to the void for general waterproofing of slabs with vehicular traffic it is recommended

    that the entire slab be coated with MAXSEAL FLEX and covered with an abrasion resistant coating such as a

    concrete or asphaltic topping after 7 days.

  5. This process may also be used in a negative situation, please contact this office for more information.

 

Note – This information is based on information from the manufacturer and from our own experience.

The information contained in this specification should be used in conjunction with the appropriate technical

data bulletins and material safety data sheets available from our office or website.